A. Substantially constructed line brattice shall be used from the last open crosscut of an entry or room when necessary to provide adequate ventilation for the miners and to remove gases. Any line brattice that is damaged by a fall or otherwise shall be repaired promptly.
B. The space between the line brattice and the rib shall be large enough to permit the flow of a sufficient volume of air to keep the working face clear of flammable and noxious gases.
C. Brattice cloth that is used underground shall be of flame-resistant material.
D. An accumulation of methane shall be moved only by means of properly installed line brattice or other approved method.
Code 1950, § 45-60.4; 1954, c. 191; 1966, c. 594, § 45.1-61; 1994, c. 28, § 45.1-161.226; 1996, c. 774; 2021, Sp. Sess. I, c. 387.
Structure Code of Virginia
Title 45.2 - Mines, Minerals, and Energy
Chapter 8 - Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc
§ 45.2-800. Face and other equipment
§ 45.2-801. Shop and other equipment
§ 45.2-803. Surface electrical installations
§ 45.2-804. Surface transformers
§ 45.2-805. Underground transformers
§ 45.2-806. Stations and substations
§ 45.2-808. Trolley wires and feeder wires
§ 45.2-810. Circuit breakers and switches
§ 45.2-811. Communication systems
§ 45.2-812. Electrical equipment
§ 45.2-814. Inspection of electrical equipment and wiring; checking and testing methane monitors
§ 45.2-815. Repairs to circuits and electric equipment
§ 45.2-816. Underground illumination
§ 45.2-817. Inspection of electric illumination equipment
§ 45.2-818. Firefighting equipment; fire prevention
§ 45.2-819. Duties in case of fire
§ 45.2-820. Emergency response plans; list of next of kin
§ 45.2-821. Reporting fires; response
§ 45.2-822. Fire prevention in transportation of mining equipment
§ 45.2-823. Storage and use of flammable fluids and materials
§ 45.2-824. Diesel-powered equipment
§ 45.2-825. Arcs, sparks, and flames
§ 45.2-826. Pre-shift examinations
§ 45.2-827. on-shift examinations
§ 45.2-828. Weekly examinations
§ 45.2-829. Examinations of fans
§ 45.2-830. Record of examinations
§ 45.2-831. Notice of hazardous conditions
§ 45.2-832. Notice of monitor tampering prohibition
§ 45.2-839. Actions for excessive methane
§ 45.2-841. Permanent stoppings
§ 45.2-842. Ventilation controls
§ 45.2-844. Ventilation with air from certain areas
§ 45.2-847. Examination of mine for explosive gas and other hazardous conditions
§ 45.2-848. Tampering with methane monitoring devices prohibited; penalty
§ 45.2-850. Intentionally bypassing a safety device; prohibition
§ 45.2-851. Control of coal dust
§ 45.2-853. Checking system; tracking system
§ 45.2-854. Protective clothing
§ 45.2-855. Noise levels and ear protection
§ 45.2-856. Smoking materials prohibited; penalty
§ 45.2-857. Allowing persons to work in a mine with smoker's articles; penalty
§ 45.2-859. Smoking in surface and other areas
§ 45.2-860. Portable illumination
§ 45.2-861. First aid equipment