A. Telephone service or equivalent two-way communication facilities shall be provided between the top and each landing of each main shaft or slope. A telephone or equivalent two-way communication facility shall be located on the surface within 500 feet of each main portal and installed in either a building or a box-like structure that is designed to protect the facility from damage by inclement weather. At least one of these communication facilities shall be at a location where an authorized person who is always on duty when miners are underground can see or hear the facility and respond immediately in the event of an emergency.
B. Telephone lines, other than cables, shall be carried on insulators, installed on the opposite side from power or trolley wires, and insulated adequately where they cross power or trolley wires.
C. Lightning arrestors shall be provided at each point where a telephone circuit enters the mine and at each telephone on the surface. Where the telephone circuit enters a building or structure, a lightning arrestor is required only at the point at which the circuit enters such building or structure.
D. If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, a means shall be provided to permit continued communication in the event the mine electric power fails or is cut off.
E. Communication systems equipped with audible and visual signals that become operative when telephone communication is being established between the phones of the communication station on the surface and the underground working sections shall be provided.
F. The Chief shall adopt regulations governing any disruption of communication in a mine.
Code 1950, § 45-82.4; 1954, c. 191; 1966, c. 594, § 45.1-81; 1978, c. 118; 1979, c. 315; 1994, c. 28, § 45.1-161.191; 1996, c. 774; 1999, c. 256; 2021, Sp. Sess. I, c. 387.
Structure Code of Virginia
Title 45.2 - Mines, Minerals, and Energy
Chapter 8 - Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc
§ 45.2-800. Face and other equipment
§ 45.2-801. Shop and other equipment
§ 45.2-803. Surface electrical installations
§ 45.2-804. Surface transformers
§ 45.2-805. Underground transformers
§ 45.2-806. Stations and substations
§ 45.2-808. Trolley wires and feeder wires
§ 45.2-810. Circuit breakers and switches
§ 45.2-811. Communication systems
§ 45.2-812. Electrical equipment
§ 45.2-814. Inspection of electrical equipment and wiring; checking and testing methane monitors
§ 45.2-815. Repairs to circuits and electric equipment
§ 45.2-816. Underground illumination
§ 45.2-817. Inspection of electric illumination equipment
§ 45.2-818. Firefighting equipment; fire prevention
§ 45.2-819. Duties in case of fire
§ 45.2-820. Emergency response plans; list of next of kin
§ 45.2-821. Reporting fires; response
§ 45.2-822. Fire prevention in transportation of mining equipment
§ 45.2-823. Storage and use of flammable fluids and materials
§ 45.2-824. Diesel-powered equipment
§ 45.2-825. Arcs, sparks, and flames
§ 45.2-826. Pre-shift examinations
§ 45.2-827. on-shift examinations
§ 45.2-828. Weekly examinations
§ 45.2-829. Examinations of fans
§ 45.2-830. Record of examinations
§ 45.2-831. Notice of hazardous conditions
§ 45.2-832. Notice of monitor tampering prohibition
§ 45.2-839. Actions for excessive methane
§ 45.2-841. Permanent stoppings
§ 45.2-842. Ventilation controls
§ 45.2-844. Ventilation with air from certain areas
§ 45.2-847. Examination of mine for explosive gas and other hazardous conditions
§ 45.2-848. Tampering with methane monitoring devices prohibited; penalty
§ 45.2-850. Intentionally bypassing a safety device; prohibition
§ 45.2-851. Control of coal dust
§ 45.2-853. Checking system; tracking system
§ 45.2-854. Protective clothing
§ 45.2-855. Noise levels and ear protection
§ 45.2-856. Smoking materials prohibited; penalty
§ 45.2-857. Allowing persons to work in a mine with smoker's articles; penalty
§ 45.2-859. Smoking in surface and other areas
§ 45.2-860. Portable illumination
§ 45.2-861. First aid equipment