A. Prior to moving or transporting any piece of off-track mining equipment in any area of the active workings where energized trolley wires or trolley feeder wires are present, (i) the piece of equipment shall be examined by a certified person to ensure that accumulations of coal dust, float coal dust, loose coal, oil, grease, and other combustible materials have been removed from such piece of equipment and (ii) a qualified person shall examine the trolley wires, trolley feeder wires, and the associated automatic circuit interrupting devices to ensure that proper short circuit protection exists.
B. A record shall be kept of the examinations required pursuant to subsection A and shall be made available, upon request, to the Chief or his authorized representative.
C. Off-track mining equipment shall not be moved or transported in any area of the active workings where energized trolley wires or trolley feeder wires are present unless under the direct supervision of a certified person who is physically present at all times during the moving or transporting of such equipment.
D. The frame of any unit of off-track mining equipment that is being moved or transported shall be covered on the top and on the trolley wire side with fire-resistant material.
E. Electrical contact shall be maintained between the mine track and the frame of any piece of off-track mining equipment that is being moved in a track and trolley entry. However, rubber-tired equipment need not be grounded to a transporting vehicle if no metal part of such rubber-tired equipment can come into contact with the transporting vehicle.
F. To avoid accidental contact with power lines, the equipment being transported or trammed shall be insulated or, if necessary, the assemblage shall be removed if the clearance to the power lines is six inches or less.
G. Sufficient prior notice shall be given to the Department so that a mine inspector, if he deems it necessary, can travel the route of the move before the actual move is made.
H. A minimum vertical clearance of one foot shall be maintained between the farthest projection of the piece of equipment that is being moved and the energized trolley wires or trolley feeder wires at all times during the movement or transportation of such equipment. If the height of the coal seam does not permit one foot of vertical clearance to be so maintained, the following additional precautions shall be taken:
1. Electric power shall be supplied to the trolley wires or trolley feeder wires only from outby the piece of equipment being moved or transported. Where direct current electric power is used and such electric power can be supplied only from inby the equipment being moved or transported, such power may be supplied from inby such equipment if a miner who has the means to cut off the power is in direct communication with the persons actually engaged in the moving or transporting operation and is stationed outby the equipment being moved;
2. The settings of automatic circuit interrupting devices used to provide short circuit protection for the trolley circuit shall be reduced to not more than one-half of the maximum current that could flow if the equipment being moved or transported were to come into contact with the trolley wire or trolley feeder wire;
3. At all times when the piece of equipment is being moved or transported, a miner shall be stationed at the first automatic circuit breaker outby the equipment being moved. Such miner shall be (i) in direct communication with the persons actually engaged in the moving or transporting operation and (ii) capable of communicating with the authorized person on the surface who is required to be on duty;
4. Where trolley phones are utilized to satisfy the requirements of subdivision 3, telephones or other equivalent two-way communication devices that can readily be connected with the mine communication system shall be carried by (i) the miner who is stationed at the first automatic circuit breaker outby the equipment being moved and (ii) by a miner who is actually engaged in the moving or transporting operation; and
5. No person shall be permitted to be inby the piece of equipment being moved or transported, or in the ventilating current of air that is passing over such equipment, except a person who is directly engaged in moving such equipment.
I. The provisions of subsection H shall not apply to a piece of mining equipment that is transported in a mine car if no part of the equipment extends above or over the sides of the mine car.
Code 1950, § 45-14.1; 1954, c. 191; 1966, c. 594, § 45.1-89; 1974, c. 323; 1978, c. 118; 1984, c. 590; 1985, c. 500; 1994, c. 28, § 45.1-161.204; 2021, Sp. Sess. I, c. 387.
Structure Code of Virginia
Title 45.2 - Mines, Minerals, and Energy
Chapter 8 - Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc
§ 45.2-800. Face and other equipment
§ 45.2-801. Shop and other equipment
§ 45.2-803. Surface electrical installations
§ 45.2-804. Surface transformers
§ 45.2-805. Underground transformers
§ 45.2-806. Stations and substations
§ 45.2-808. Trolley wires and feeder wires
§ 45.2-810. Circuit breakers and switches
§ 45.2-811. Communication systems
§ 45.2-812. Electrical equipment
§ 45.2-814. Inspection of electrical equipment and wiring; checking and testing methane monitors
§ 45.2-815. Repairs to circuits and electric equipment
§ 45.2-816. Underground illumination
§ 45.2-817. Inspection of electric illumination equipment
§ 45.2-818. Firefighting equipment; fire prevention
§ 45.2-819. Duties in case of fire
§ 45.2-820. Emergency response plans; list of next of kin
§ 45.2-821. Reporting fires; response
§ 45.2-822. Fire prevention in transportation of mining equipment
§ 45.2-823. Storage and use of flammable fluids and materials
§ 45.2-824. Diesel-powered equipment
§ 45.2-825. Arcs, sparks, and flames
§ 45.2-826. Pre-shift examinations
§ 45.2-827. on-shift examinations
§ 45.2-828. Weekly examinations
§ 45.2-829. Examinations of fans
§ 45.2-830. Record of examinations
§ 45.2-831. Notice of hazardous conditions
§ 45.2-832. Notice of monitor tampering prohibition
§ 45.2-839. Actions for excessive methane
§ 45.2-841. Permanent stoppings
§ 45.2-842. Ventilation controls
§ 45.2-844. Ventilation with air from certain areas
§ 45.2-847. Examination of mine for explosive gas and other hazardous conditions
§ 45.2-848. Tampering with methane monitoring devices prohibited; penalty
§ 45.2-850. Intentionally bypassing a safety device; prohibition
§ 45.2-851. Control of coal dust
§ 45.2-853. Checking system; tracking system
§ 45.2-854. Protective clothing
§ 45.2-855. Noise levels and ear protection
§ 45.2-856. Smoking materials prohibited; penalty
§ 45.2-857. Allowing persons to work in a mine with smoker's articles; penalty
§ 45.2-859. Smoking in surface and other areas
§ 45.2-860. Portable illumination
§ 45.2-861. First aid equipment