A. Trolley wires and trolley feeder wires shall be installed on the side of the entry opposite the clearance space and any shelter hole, except where the wires are guarded or are installed at least 6.5 feet above the top of the rail.
B. Trolley-wire hangers shall be so spaced that the wire may become detached from any one hanger without creating a shock hazard.
C. Trolley wires shall be aligned properly and installed on insulated hangers at least six inches outside the rail.
D. Trolley wires and trolley feeder wires shall be provided with cut-out switches at intervals of not more than 1,500 feet and near the beginning of each branch line.
E. Trolley wires and trolley feeder wires shall be kept taut and shall not be permitted to touch the roof or any rib, timber, or combustible material.
F. Trolley wires and trolley feeder wires shall be guarded adequately at both sides of any door and at every place where miners work or pass under them, unless they are at least 6.5 feet above the top of the rail.
G. No trolley wires or trolley feeder wires shall extend beyond any open crosscut between an intake and a return airway. All such wires shall be kept at least 150 feet from any active, open pillar workings.
H. Trolley wires and trolley feeder wires shall be guarded, anchored securely, and insulated properly at the ends.
I. Trolley wires and trolley feeder wires shall be installed only in an intake airway.
J. No trolley wires or other exposed conductors shall carry more than 300 volts.
Code 1950, §§ 45-82, 45-82.1; 1954, c. 191; 1966, c. 594, § 45.1-78; 1993, c. 442; 1994, c. 28, § 45.1-161.187; 1996, c. 774; 1999, c. 256; 2021, Sp. Sess. I, c. 387.
Structure Code of Virginia
Title 45.2 - Mines, Minerals, and Energy
Chapter 8 - Requirements Applicable to Underground Coal Mines; Electricity, Safety, Etc
§ 45.2-800. Face and other equipment
§ 45.2-801. Shop and other equipment
§ 45.2-803. Surface electrical installations
§ 45.2-804. Surface transformers
§ 45.2-805. Underground transformers
§ 45.2-806. Stations and substations
§ 45.2-808. Trolley wires and feeder wires
§ 45.2-810. Circuit breakers and switches
§ 45.2-811. Communication systems
§ 45.2-812. Electrical equipment
§ 45.2-814. Inspection of electrical equipment and wiring; checking and testing methane monitors
§ 45.2-815. Repairs to circuits and electric equipment
§ 45.2-816. Underground illumination
§ 45.2-817. Inspection of electric illumination equipment
§ 45.2-818. Firefighting equipment; fire prevention
§ 45.2-819. Duties in case of fire
§ 45.2-820. Emergency response plans; list of next of kin
§ 45.2-821. Reporting fires; response
§ 45.2-822. Fire prevention in transportation of mining equipment
§ 45.2-823. Storage and use of flammable fluids and materials
§ 45.2-824. Diesel-powered equipment
§ 45.2-825. Arcs, sparks, and flames
§ 45.2-826. Pre-shift examinations
§ 45.2-827. on-shift examinations
§ 45.2-828. Weekly examinations
§ 45.2-829. Examinations of fans
§ 45.2-830. Record of examinations
§ 45.2-831. Notice of hazardous conditions
§ 45.2-832. Notice of monitor tampering prohibition
§ 45.2-839. Actions for excessive methane
§ 45.2-841. Permanent stoppings
§ 45.2-842. Ventilation controls
§ 45.2-844. Ventilation with air from certain areas
§ 45.2-847. Examination of mine for explosive gas and other hazardous conditions
§ 45.2-848. Tampering with methane monitoring devices prohibited; penalty
§ 45.2-850. Intentionally bypassing a safety device; prohibition
§ 45.2-851. Control of coal dust
§ 45.2-853. Checking system; tracking system
§ 45.2-854. Protective clothing
§ 45.2-855. Noise levels and ear protection
§ 45.2-856. Smoking materials prohibited; penalty
§ 45.2-857. Allowing persons to work in a mine with smoker's articles; penalty
§ 45.2-859. Smoking in surface and other areas
§ 45.2-860. Portable illumination
§ 45.2-861. First aid equipment