A. Every shaft shall be equipped with safety gates at the top and at each landing. Safety gates shall be kept closed except when the cage is being loaded or unloaded.
B. At the bottom of each hoisting shaft and at each intermediate landing, a runaround shall be provided for safe passage from one side of the shaft to the other. This passageway shall be at least five feet in height and three feet in width.
C. Ice shall not be permitted to accumulate excessively in any shaft where miners are hoisted or lowered.
D. Positive-acting stopblocks or derails shall be installed near the top and at intermediate landings of slopes and surface inclines and at the approaches to all shaft landings.
E. Positive-acting stopblocks or derails shall be installed on the haulage track in the slope near the top of the slope. The stopblocks or derails shall be in a position to hold or stop any load to be lowered into the mine, including heavy mining equipment, until such time as the equipment is to be lowered into the mine by the hoist.
Code 1950, § 45-68.4; 1954, c. 191; 1966, c. 594, §§ 45.1-69, 45.1-89.1; 1978, c. 729; 1983, c. 111; 1994, c. 28, § 45.1-161.156; 1996, c. 774; 2005, c. 3; 2021, Sp. Sess. I, c. 387.
Structure Code of Virginia
Title 45.2 - Mines, Minerals, and Energy
Chapter 7 - Requirements Applicable to Underground Coal Mines; Mine Construction
§ 45.2-701. Regulations governing conditions and practices at underground coal mines
§ 45.2-702. Standards for regulations
§ 45.2-703. Duties of mine foreman
§ 45.2-704. Employment and duties of top persons; plan for excavation of shaft or slope
§ 45.2-705. Employment of inexperienced underground miners
§ 45.2-706. Employment of authorized persons
§ 45.2-707. Mining in proximity to gas or oil wells
§ 45.2-708. Mining in proximity to an abandoned area
§ 45.2-709. Roof, face, and ribs to be secure
§ 45.2-710. Roof control plans
§ 45.2-711. Instruction of miners
§ 45.2-713. Automated temporary roof support systems
§ 45.2-714. Supplies of materials for supports
§ 45.2-715. Examination and testing of roof, face, and ribs
§ 45.2-716. Mapping of roof falls
§ 45.2-718. Removal of supports
§ 45.2-719. Surface storage of explosives and detonators
§ 45.2-720. Underground transportation of explosives and detonators
§ 45.2-721. Underground storage of explosives and detonators
§ 45.2-722. Blasting practices; penalty
§ 45.2-725. Explosives and blasting practices in shaft and slope operations
§ 45.2-727. Separation of openings
§ 45.2-728. Number of miners in openings
§ 45.2-729. Maintenance of mine openings
§ 45.2-730. Signs, life lines, and equipment
§ 45.2-731. Examination of escapeways
§ 45.2-732. Longwall escape routes and plan
§ 45.2-735. Hoisting equipment
§ 45.2-738. Shaft and slope conditions
§ 45.2-739. Signaling; signal code
§ 45.2-740. Inspections of hoisting equipment
§ 45.2-741. Hoisting engineers
§ 45.2-742. Operations of hoisting equipment
§ 45.2-743. Maintenance of hoisting equipment
§ 45.2-745. Track switches and rails
§ 45.2-746. Clearance on haulage roads
§ 45.2-747. Conveyor crossings
§ 45.2-749. Refuge from moving traffic
§ 45.2-750. Inspection of underground equipment
§ 45.2-751. Maintenance of equipment
§ 45.2-752. Self-propelled equipment
§ 45.2-754. Transportation of material
§ 45.2-758. Operation of equipment
§ 45.2-760. Availability of mantrips
§ 45.2-762. Mantrip loading and unloading areas
§ 45.2-763. Transporting miners by conveyor belt
§ 45.2-764. Housekeeping; noxious fumes
§ 45.2-766. Flammable or combustible materials
§ 45.2-767. Hazardous crane operations
§ 45.2-768. Controlling dust at the surface
§ 45.2-769. Scaffolding and overhead protection
§ 45.2-770. Welding and cutting
§ 45.2-771. Fire prevention and fire control