§ 45.2-719. Surface storage of explosives and detonators

A. Two or more surface magazines shall be provided for the storage of explosives and the separate storage of detonators.
B. Every surface magazine for storing and distributing explosives in an amount exceeding 150 pounds shall be:
1. Reasonably bullet-resistant and constructed of incombustible material or covered with fire-resistant material. The roof of a magazine that is located in such a way as to make it impossible to fire a bullet directly through the roof from the ground need not be bullet-resistant. Where it is possible to fire a bullet directly through a roof from the ground, such roof shall be made bullet-resistant by material construction, by the use of a ceiling that forms a tray containing not less than a four-inch thickness of sand, or by another method;
2. Provided with doors that are constructed of three-eighth-inch steel plate. Such doors shall be lined with a two-inch thickness of wood or the equivalent;
3. Provided with dry floors that are made of wood or other nonsparking material and have no metal exposed inside the magazine;
4. Provided with suitable warning signs located so that a bullet passing directly through the face of a sign will not strike the magazine;
5. Provided with properly screened ventilators;
6. Equipped with no openings except for entrance and ventilation openings;
7. Kept locked securely when unattended; and
8. Electrically bonded and grounded if constructed of metal.
C. A surface magazine for storing detonators need not be bullet-resistant, but it shall comply with the other provisions of subsection B regarding the storage of explosives.
D. Explosives weighing a total of no more than 150 pounds, or detonators numbering 5,000 or fewer, shall be stored (i) in accordance with the standards set forth in subsection A, B, or C or (ii) in a separate locked box-type magazine. A box-type magazine may also be used as a distributing magazine when the weight of the explosives or the number of detonators does not exceed the limits set forth in this subsection. Every box-type magazine shall be strongly constructed of two-inch hardwood or the equivalent. Every metal magazine shall be lined with nonsparking material. No magazine shall be placed (a) in a building containing oil, grease, gasoline, wastepaper, or other highly flammable material or (b) within 20 feet of a stove, furnace, open fire, or flame.
E. No magazine shall be placed less than 300 feet from any mine opening. However, if a magazine cannot be practicably located at such distance, it may be located less than 300 feet from a mine opening if it is sufficiently barricaded and is approved by the Chief. Unless approved by the Chief, no magazine shall be located closer to an occupied building, public road, or passenger railway than the distance recommended in the "American Table of Distances for Storage of Explosive Materials" published by the Institute of Makers of Explosives.
F. The supply kept in a distribution magazine shall be limited to approximately a 48-hour supply, and supplies of explosives and detonators may be distributed from the same magazine if they are separated by a substantially fastened hardwood partition at least four inches thick or the equivalent.
G. The area surrounding any magazine shall be kept free of rubbish, dry grass, or other materials of a combustible nature for at least 25 feet in every direction.
H. If an explosives magazine is illuminated electrically, each lamp shall be vapor-proof and installed and wired so as to minimize any fire or contact hazard.
I. Only nonmetallic tools shall be used for opening any wooden explosives container. Extraneous materials shall not be stored with explosives or detonators in an explosives magazine.
J. Smoking or carrying smokers' articles or open flames is prohibited in or near any magazine.
Code 1950, § 45-53.2; 1954, c. 191; 1966, c. 594, § 45.1-44; 1978, c. 729; 1994, c. 28, § 45.1-161.126; 2005, c. 3; 2021, Sp. Sess. I, c. 387.

Structure Code of Virginia

Code of Virginia

Title 45.2 - Mines, Minerals, and Energy

Chapter 7 - Requirements Applicable to Underground Coal Mines; Mine Construction

§ 45.2-700. Scope of chapter

§ 45.2-701. Regulations governing conditions and practices at underground coal mines

§ 45.2-702. Standards for regulations

§ 45.2-703. Duties of mine foreman

§ 45.2-704. Employment and duties of top persons; plan for excavation of shaft or slope

§ 45.2-705. Employment of inexperienced underground miners

§ 45.2-706. Employment of authorized persons

§ 45.2-707. Mining in proximity to gas or oil wells

§ 45.2-708. Mining in proximity to an abandoned area

§ 45.2-709. Roof, face, and ribs to be secure

§ 45.2-710. Roof control plans

§ 45.2-711. Instruction of miners

§ 45.2-712. Copies of plan

§ 45.2-713. Automated temporary roof support systems

§ 45.2-714. Supplies of materials for supports

§ 45.2-715. Examination and testing of roof, face, and ribs

§ 45.2-716. Mapping of roof falls

§ 45.2-717. Unsafe conditions

§ 45.2-718. Removal of supports

§ 45.2-719. Surface storage of explosives and detonators

§ 45.2-720. Underground transportation of explosives and detonators

§ 45.2-721. Underground storage of explosives and detonators

§ 45.2-722. Blasting practices; penalty

§ 45.2-723. Blasting cables

§ 45.2-724. Misfires

§ 45.2-725. Explosives and blasting practices in shaft and slope operations

§ 45.2-726. Mine openings

§ 45.2-727. Separation of openings

§ 45.2-728. Number of miners in openings

§ 45.2-729. Maintenance of mine openings

§ 45.2-730. Signs, life lines, and equipment

§ 45.2-731. Examination of escapeways

§ 45.2-732. Longwall escape routes and plan

§ 45.2-733. Fire protection

§ 45.2-734. Unused openings

§ 45.2-735. Hoisting equipment

§ 45.2-736. Hoisting ropes

§ 45.2-737. Hoisting cages

§ 45.2-738. Shaft and slope conditions

§ 45.2-739. Signaling; signal code

§ 45.2-740. Inspections of hoisting equipment

§ 45.2-741. Hoisting engineers

§ 45.2-742. Operations of hoisting equipment

§ 45.2-743. Maintenance of hoisting equipment

§ 45.2-744. Haulage roads

§ 45.2-745. Track switches and rails

§ 45.2-746. Clearance on haulage roads

§ 45.2-747. Conveyor crossings

§ 45.2-748. Shelter holes

§ 45.2-749. Refuge from moving traffic

§ 45.2-750. Inspection of underground equipment

§ 45.2-751. Maintenance of equipment

§ 45.2-752. Self-propelled equipment

§ 45.2-753. Pushing cars

§ 45.2-754. Transportation of material

§ 45.2-755. Securing cars

§ 45.2-756. Riding on cars

§ 45.2-757. Back-poling

§ 45.2-758. Operation of equipment

§ 45.2-759. Dispatchers

§ 45.2-760. Availability of mantrips

§ 45.2-761. Mantrips

§ 45.2-762. Mantrip loading and unloading areas

§ 45.2-763. Transporting miners by conveyor belt

§ 45.2-764. Housekeeping; noxious fumes

§ 45.2-765. Lighting

§ 45.2-766. Flammable or combustible materials

§ 45.2-767. Hazardous crane operations

§ 45.2-768. Controlling dust at the surface

§ 45.2-769. Scaffolding and overhead protection

§ 45.2-770. Welding and cutting

§ 45.2-771. Fire prevention and fire control

§ 45.2-772. Surface equipment

§ 45.2-773. Travel ways and loading and haulage areas

§ 45.2-774. Electricity

§ 45.2-775. Surface blasting

§ 45.2-776. Ground control