Effective: March 27, 2013
Latest Legislation: House Bill 458 - 129th General Assembly
(A) When making excavations using traditional or trenchless technologies, the excavator shall do all of the following:
(1) Maintain reasonable clearance between any underground facility and the cutting edge or point of powered equipment;
(2) Protect and preserve the markings of tolerance zones of underground utility facilities until those markings are no longer required for proper and safe excavations;
(3) When approaching and excavating within the tolerance zone of underground utility facilities with powered equipment, require an individual other than the equipment operator, to visually monitor the excavation activity for any indication of the underground utility facility;
(4) Conduct the excavation within the tolerance zone of underground utility facilities in a careful, prudent, and nondestructive manner, when necessary, in order to prevent damage;
(5) Excavate up to the total depth of the excavation to either determine the precise location of underground utility facilities or verify that the total depth of excavation is free of such facilities;
(6) As soon as any damage is discovered, including gouges, dents, or breaks to coatings, cable sheathes, and cathodic protection anodes or wiring, report the type and location of the damage to the utility and permit the utility a reasonable amount of time to make necessary repairs;
(7) Immediately report to the utility, the protection service, and, if necessary, to the appropriate law enforcement agencies and fire departments by calling 9-1-1, any damage to an underground utility facility that results in escaping flammable, corrosive, explosive, or toxic liquids or gas, and take reasonable appropriate actions needed to protect persons and property and to minimize safety hazards until those agencies and departments and the utility arrive at the scene.
(B) When utilizing trenchless excavation methods, the excavator must comply with the following requirements, in a manner consistent with division (A) of this section:
(1) Expose and confirm all underground utility facilities at each crossing point by the proposed excavation in a nondestructive manner to the installation depth of the new facility;
(2) Expose all parallel underground utility facilities in a nondestructive manner at the beginning and end of each trenchless excavation to the installation depth of the new facility. If the proposed alignment is within the tolerance zone of any parallel underground utility facility, the underground utility facility shall be exposed every one hundred feet.
(3) Ensure that the final product installation maintains the proper clearances of existing underground utility facilities as determined pursuant to division (E)(4) of section 3781.27 of the Revised Code.
Structure Ohio Revised Code
Title 37 | Health-Safety-Morals
Chapter 3781 | Building Standards - General Provisions
Section 3781.01 | Municipal Corporation May Make Additional Regulations.
Section 3781.02 | Exceptions to Certain Requirements.
Section 3781.03 | Enforcement - Supervision - Records.
Section 3781.031 | Issuance of Adjudication or Stop Work Order.
Section 3781.04 | Jurisdiction for Violations of Building Standards.
Section 3781.05 | Plumbing Standards for Veterans' Emergency Housing.
Section 3781.06 | Public Buildings to Be Safe and Sanitary - Definitions.
Section 3781.061 | Exemption for Building or Structure Used in Agriculture.
Section 3781.07 | Organization of Board - Employees.
Section 3781.08 | Rules of Procedure.
Section 3781.09 | Rules of Procedure.
Section 3781.10 | Board of Building Standards - Powers and Duties.
Section 3781.101 | Proceedings of the Board of Building Standards.
Section 3781.102 | Extending Building Department Certifications.
Section 3781.103 | Deadbolt Locks or Equivalent Security Locking Device for Swinging Exit Doors.
Section 3781.105 | Certification of Fire Protection System Designers.
Section 3781.106 | Devices to Regulate Ingress and Egress Through Doors in Specified Buildings.
Section 3781.107 | Hotel to Have Available Fire Warning Device Producing Visible Warning Signal.
Section 3781.109 | Rest Room Facilities.
Section 3781.1010 | Rules Regarding Installation of Storm Shelters on Certain School Buildings.
Section 3781.1011 | Battery-Charged Fences.
Section 3781.11 | Rules of Board of Building Standards - Public Nuisance.
Section 3781.112 | Security Facility May Use Delayed Egress and Coded Doors.
Section 3781.12 | Petition for Adoption, Amendment or Annulment of Rule or Regulation.
Section 3781.13 | Petition for Hearing on Action of Board.
Section 3781.14 | Court Action Against Board of Building Standards.
Section 3781.15 | Injunction Proceedings.
Section 3781.16 | Effect on Municipal or Other State Authorities.
Section 3781.17 | Assistance by Commerce Department.
Section 3781.18 | Certain Descriptions Prescribe Minimum Standards.
Section 3781.184 | Federal Manufactured Home Construction and Safety Standards.
Section 3781.19 | Board of Building Appeals.
Section 3781.191 | Board Jurisdiction Regarding Residential Building Code.
Section 3781.20 | Municipal and County Boards of Building Appeals.
Section 3781.25 | One-Call Utility Protection Service Definitions.
Section 3781.26 | Protection Service for Underground Utility Facilities.
Section 3781.261 | Protection of Underground Utility Facilities Training.
Section 3781.27 | Developer or Designer Notifying Protection Service of Intended Excavation.
Section 3781.271 | Modification of One-Call Notification System.
Section 3781.28 | Excavator Notifying Protection Service or Pipeline Owner.
Section 3781.29 | Marking Location of Facilities or Give Notice of No Facilities at Site.
Section 3781.30 | Duties of Excavator.
Section 3781.31 | Notifying of Commencement of Excavation or of Removal of Markings.
Section 3781.32 | Connections or Tie-Ins Within Right-of-Way.
Section 3781.34 | Underground Technical Committee.
Section 3781.341 | Conflicts of Interest.
Section 3781.343 | Disclosure Requirements.
Section 3781.36 | Duties of Committee.
Section 3781.38 | Member Immunity.
Section 3781.40 | Welding Standards.
Section 3781.55 | Breast-Feeding in Places of Public Accommodation.