Ohio Revised Code
Chapter 3781 | Building Standards - General Provisions
Section 3781.25 | One-Call Utility Protection Service Definitions.

Effective: March 23, 2015
Latest Legislation: Senate Bill 378 - 130th General Assembly
As used in sections 3781.25 to 3781.38 of the Revised Code:
(A) "Protection service" means a notification center, but not an owner of an individual utility, that exists for the purpose of receiving notice from persons that prepare plans and specifications for or that engage in excavation work, that distributes this information to its members and participants, and that has registered by March 14, 1989, with the secretary of state and the public utilities commission of Ohio under former division (F) of section 153.64 of the Revised Code as it existed on that date.
(B) "Underground utility facility" includes any item buried or placed below ground or submerged under water for use in connection with the storage or conveyance of water or sewage; electronic, telephonic, or telegraphic communications; television signals; electricity; crude oil; petroleum products; artificial or liquefied petroleum; manufactured, mixed, or natural gas; synthetic or liquefied natural gas; propane gas; coal; steam; hot water; or other substances. "Underground utility facility" includes all operational underground pipes, sewers, tubing, conduits, cables, valves, lines, wires, worker access holes, and attachments, owned by any person, firm, or company. "Underground utility facility" does not include a private septic system in a one-family or multi-family dwelling utilized only for that dwelling and not connected to any other system.
(C) "Utility" means any owner or operator, or an agent of an owner or operator, of an underground utility facility, including any public authority, that owns or operates an underground utility facility. "Utility" does not include the owners of the following types of real property with respect to any underground utility facility located on that property:
(1) The owner of a single-family or two-, three-, or four-unit residential dwelling;
(2) The owner of an apartment complex;
(3) The owner of a commercial or industrial building or complex of buildings, including but not limited to, factories and shopping centers;
(4) The owner of a farm;
(5) The owner of an exempt domestic well as defined in section 1509.01 of the Revised Code.
(D) "Approximate location" means the immediate area within the perimeter of a proposed excavation site where the underground utility facilities are located.
(E) "Tolerance zone" means the site of the underground utility facility including the width of the underground utility facility plus eighteen inches on each side of the facility.
(F) "Working days" excludes Saturdays, Sundays, and legal holidays as defined in section 1.14 of the Revised Code and "hours" excludes hours on Saturdays, Sundays, and legal holidays.
(G) "Designer" means an engineer, architect, landscape architect, contractor, surveyor, or other person who develops plans or designs for real property improvement or any other activity that will involve excavation.
(H) "Developer" means the person for whom the excavation is made and who will own or be the lessee of any improvement that is the object of the excavation.
(I) "Excavation" means the use of hand tools, powered equipment, or explosives to move earth, rock, or other materials in order to penetrate or bore or drill into the earth, or to demolish any structure whether or not it is intended that the demolition will disturb the earth. "Excavation" includes such agricultural operations as the installation of drain tile, but excludes agricultural operations such as tilling that do not penetrate the earth to a depth of more than twelve inches. "Excavation" excludes any activity by a governmental entity which does not penetrate the earth to a depth of more than twelve inches. "Excavation" excludes coal mining and reclamation operations regulated under Chapter 1513. of the Revised Code and rules adopted under it.
(J) "Excavation site" means the area within which excavation will be performed.
(K) "Excavator" means the person or persons responsible for making the actual excavation.
(L) "Interstate gas pipeline" means an interstate gas pipeline subject to the "Natural Gas Pipeline Safety Act of 1968," 82 Stat. 720, 49 U.S.C. 1671, as amended.
(M) "Interstate hazardous liquids pipeline" means an interstate hazardous liquids pipeline subject to the "Hazardous Liquid Pipeline Safety Act of 1979," 93 Stat. 1003, 49 U.S.C. 2002, as amended.
(N) "Special notification requirements" means requirements for notice to an owner of an interstate hazardous liquids pipeline or an interstate gas pipeline that must be made prior to commencing excavation and pursuant to the owner's public safety program adopted under federal law.
(O) "Commercial excavator" means any excavator, excluding a utility as defined in this section, that satisfies both of the following:
(1) For compensation, performs, directs, supervises, or is responsible for the excavation, construction, improvement, renovation, repair, or maintenance on a construction project and holds out or represents oneself as qualified or permitted to act as such;
(2) Employs tradespersons who actually perform excavation, construction, improvement, renovation, repair, or maintenance on a construction project.
(P) "Person" has the same meaning as in section 1.59 of the Revised Code and also includes a public authority.
(Q) "Positive response system" means an automated system facilitated by a protection service allowing a utility to communicate to an excavator the presence or absence of any conflict between the existing underground utility facilities and the proposed excavation site.
(R) "One-call notification system" means the software or communications system used by a protection system to notify its membership of proposed excavation sites.
(S) "Project" means any undertaking by a private party of an improvement requiring excavation.
(T) "Public authority" has the same meaning as in section 153.64 of the Revised Code.
(U) "Improvement" means any construction, reconstruction, improvement, enlargement, alteration, or repair of a building, highway, drainage system, water system, road, street, alley, sewer, ditch, sewage disposal plant, water works, and all other structures or works of any nature.
(V) "Emergency" means an unexpected occurrence causing a disruption or damage to an underground utility facility that requires immediate repair or a situation that creates a clear and imminent danger that demands immediate action to prevent or mitigate loss of or damage to life, health, property, or essential public services.
(W) "Nondestructive manner" means using low-impact, low-risk technologies such as hand tools, or hydro or air vacuum excavation equipment.
(X) "Cable service provider" has the same meaning as in section 1332.01 of the Revised Code.
(Y) "Electric cooperative" and "electric utility" have the same meanings as in section 4928.01 of the Revised Code.

Structure Ohio Revised Code

Ohio Revised Code

Title 37 | Health-Safety-Morals

Chapter 3781 | Building Standards - General Provisions

Section 3781.01 | Municipal Corporation May Make Additional Regulations.

Section 3781.02 | Exceptions to Certain Requirements.

Section 3781.03 | Enforcement - Supervision - Records.

Section 3781.031 | Issuance of Adjudication or Stop Work Order.

Section 3781.04 | Jurisdiction for Violations of Building Standards.

Section 3781.05 | Plumbing Standards for Veterans' Emergency Housing.

Section 3781.06 | Public Buildings to Be Safe and Sanitary - Definitions.

Section 3781.061 | Exemption for Building or Structure Used in Agriculture.

Section 3781.07 | Organization of Board - Employees.

Section 3781.08 | Rules of Procedure.

Section 3781.09 | Rules of Procedure.

Section 3781.10 | Board of Building Standards - Powers and Duties.

Section 3781.101 | Proceedings of the Board of Building Standards.

Section 3781.102 | Extending Building Department Certifications.

Section 3781.103 | Deadbolt Locks or Equivalent Security Locking Device for Swinging Exit Doors.

Section 3781.104 | Smoke Detector Systems or Sprinkler System for Apartment Buildings and Condominiums.

Section 3781.105 | Certification of Fire Protection System Designers.

Section 3781.106 | Devices to Regulate Ingress and Egress Through Doors in Specified Buildings.

Section 3781.107 | Hotel to Have Available Fire Warning Device Producing Visible Warning Signal.

Section 3781.108 | Fire Suppression System Required in Certain New Tall Buildings Used for Human Occupancy.

Section 3781.109 | Rest Room Facilities.

Section 3781.1010 | Rules Regarding Installation of Storm Shelters on Certain School Buildings.

Section 3781.1011 | Battery-Charged Fences.

Section 3781.11 | Rules of Board of Building Standards - Public Nuisance.

Section 3781.111 | Facilitating Reasonable Access and Use by All Persons With Disability of Buildings and Facilities of Buildings.

Section 3781.112 | Security Facility May Use Delayed Egress and Coded Doors.

Section 3781.12 | Petition for Adoption, Amendment or Annulment of Rule or Regulation.

Section 3781.13 | Petition for Hearing on Action of Board.

Section 3781.14 | Court Action Against Board of Building Standards.

Section 3781.15 | Injunction Proceedings.

Section 3781.16 | Effect on Municipal or Other State Authorities.

Section 3781.17 | Assistance by Commerce Department.

Section 3781.18 | Certain Descriptions Prescribe Minimum Standards.

Section 3781.184 | Federal Manufactured Home Construction and Safety Standards.

Section 3781.19 | Board of Building Appeals.

Section 3781.191 | Board Jurisdiction Regarding Residential Building Code.

Section 3781.20 | Municipal and County Boards of Building Appeals.

Section 3781.25 | One-Call Utility Protection Service Definitions.

Section 3781.26 | Protection Service for Underground Utility Facilities.

Section 3781.261 | Protection of Underground Utility Facilities Training.

Section 3781.27 | Developer or Designer Notifying Protection Service of Intended Excavation.

Section 3781.271 | Modification of One-Call Notification System.

Section 3781.28 | Excavator Notifying Protection Service or Pipeline Owner.

Section 3781.29 | Marking Location of Facilities or Give Notice of No Facilities at Site.

Section 3781.30 | Duties of Excavator.

Section 3781.31 | Notifying of Commencement of Excavation or of Removal of Markings.

Section 3781.32 | Connections or Tie-Ins Within Right-of-Way.

Section 3781.34 | Underground Technical Committee.

Section 3781.341 | Conflicts of Interest.

Section 3781.342 | Meetings.

Section 3781.343 | Disclosure Requirements.

Section 3781.36 | Duties of Committee.

Section 3781.38 | Member Immunity.

Section 3781.40 | Welding Standards.

Section 3781.55 | Breast-Feeding in Places of Public Accommodation.

Section 3781.99 | Penalty.