Sec. 13f.
Log walls are permitted in residential buildings if all of the following requirements are met:
(a) The log walls have a minimum average wall thickness of 5 inches or greater.
(b) The log walls comply with the international code council standard on the design and construction of log structures, ICC 400-2007, or other successor standard that the department may specify by rule.
(c) The area weighted average U-factor for fenestration products in the log walls is a maximum of 0.31.
(d) All energy efficiency requirements of this act and rules promulgated under this act applicable to components other than log walls are met.
(e) The building heating equipment is qualified under the energy star program jointly operated by the United States department of energy and the United States environmental protection agency as provided for in 10 CFR part 430 or the building heating equipment meets or exceeds the following United States department of energy ratings:
(i) For a gas furnace, an annual fuel utilization efficiency (AFUE) of 90.
(ii) For an oil furnace, an annual fuel utilization efficiency (AFUE) of 85.
(iii) For a boiler, an annual fuel utilization efficiency (AFUE) of 85.
(iv) For a split system air source heat pump, an 8.2 heating seasonal performance factor (HSPF).
(v) For a closed loop water-to-air geothermal heat pump, an energy efficiency rating of 14.1 and a coefficient of performance of 3.3.
(vi) For an open loop water-to-air geothermal heat pump, an energy efficiency rating of 16.2 and a coefficient of performance of 3.6.
(vii) For a closed loop water-to-water geothermal heat pump, an energy efficiency rating of 15.1 and a coefficient of performance of 3.0.
(viii) For an open loop water-to-water geothermal heat pump, an energy efficiency rating of 19.1 and a coefficient of performance of 3.4.
(ix) For a direct geothermal exchange, an energy efficiency rating of 15.0 and a coefficient of performance of 3.5.
History: Add. 2012, Act 264, Imd. Eff. July 3, 2012 Popular Name: Act 230Popular Name: Uniform Construction Code
Structure Michigan Compiled Laws
Chapter 125 - Planning, Housing, and Zoning
Act 230 of 1972 - Stille-Derossett-Hale Single State Construction Code Act (125.1501 - 125.1531)
Section 125.1501 - Short Title.
Section 125.1502 - Repealed. 1999, Act 245, Eff. July 31, 2001.
Section 125.1502a - Additional Definitions.
Section 125.1503 - Repealed. 1999, Act 245, Eff. July 31, 2001.
Section 125.1504a - Repealed. 1985, Act 220, Eff. Jan. 13, 1988.
Section 125.1504b - Bed and Breakfast.
Section 125.1504h - Installation of Manual Fire Alarm Box Required in Schools; Exception.
Section 125.1505 - Powers of Commission.
Section 125.1506 - Rules; Promulgation; Copies; Exceptions.
Section 125.1508 - Repealed. 1999, Act 245, Eff. July 31, 2001.
Section 125.1508a - Applicability of Act and State Construction Code.
Section 125.1508b - Administration and Enforcement of Act and Code.
Section 125.1509 - Contract With Private Organization.
Section 125.1509a - Repealed. 1999, Act 245, Eff. July 31, 2001.
Section 125.1509b - Performance Evaluation of Enforcing Agency.
Section 125.1509c - Effect of Delinquent Payment of Civil Fine, Costs, or Assessment.
Section 125.1513a - Definitions; Prohibited Appliances; Exceptions; Promulgation Date.
Section 125.1513d - Requirements for Stairwell Geometry.
Section 125.1513e - Sharing Elevator Between 2 Buildings.
Section 125.1513f - Log Walls; Requirements.
Section 125.1517 - Effect of Appeal on Orders, Determinations, Decisions, and Actions.
Section 125.1518 - Filing Claim of Appeal or Petition to Review.
Section 125.1523a - Civil Violation; Penalty; Enforcement.
Section 125.1524 - Effect of Existing Construction Regulations and Permits.
Section 125.1526 - Transfer of State Plumbing and Electrical Administrative Boards to Commission.
Section 125.1530 - Saving Clause; Pending or Subsequent Prosecutions.