RCW 70.74.050
Quantity and distance table for explosives manufacturing buildings.
All explosives manufacturing buildings shall be located one from the other and from other buildings on explosives manufacturing plants in which persons are regularly employed, and all magazines shall be located from factory buildings and buildings on explosives plants in which persons are regularly employed, in conformity with the intraexplosives plant quantity and distance table below set forth:
EXPLOSIVES
Pounds
Over
Pounds
Not Over
Distance
Feet
Separate
Building or
Within
Substantial
Dividing Walls
. . . .
10
10
25
40
25
50
60
50
100
80
100
200
100
200
300
120
300
400
130
400
500
140
500
750
160
750
1,000
180
1,000
1,500
210
1,500
2,000
230
2,000
3,000
260
3,000
4,000
280
4,000
5,000
300
5,000
6,000
320
6,000
7,000
340
7,000
8,000
360
8,000
9,000
380
9,000
10,000
400
10,000
12,500
420
12,500
15,000
450
15,000
17,500
470
17,500
20,000
490
20,000
25,000
530
25,000
30,000
560
30,000
35,000
590
35,000
40,000
620
40,000
45,000
640
45,000
50,000
660
50,000
55,000
680
55,000
60,000
700
60,000
65,000
720
65,000
70,000
740
70,000
75,000
770
75,000
80,000
780
80,000
85,000
790
85,000
90,000
800
90,000
95,000
820
95,000
100,000
830
100,000
125,000
900
125,000
150,000
950
150,000
175,000
1,000
175,000
200,000
1,050
200,000
225,000
1,100
225,000
250,000
1,150
[ 1972 ex.s. c 88 § 8; 1931 c 111 § 5; RRS § 5440-5.]
Structure Revised Code of Washington
Title 70 - Public Health and Safety
Chapter 70.74 - Washington State Explosives Act.
70.74.013 - Funds collected by department.
70.74.020 - Restrictions on manufacture, sale, or storage—Users—Reports on storage—Waiver.
70.74.025 - Magazines—Classification, location and construction—Standards—Use.
70.74.030 - Quantity and distance tables for storage—Adoption by rule.
70.74.040 - Limit on storage quantity.
70.74.050 - Quantity and distance table for explosives manufacturing buildings.
70.74.061 - Quantity and distance tables for separation between magazines—Adoption by rule.
70.74.100 - Storage of caps with explosives prohibited.
70.74.110 - Manufacturer's report—Inspection—License.
70.74.120 - Storage report—Inspection—License—Cancellation.
70.74.130 - Dealer in explosives—Application—License.
70.74.135 - Purchaser of explosives—Application—License.
70.74.137 - Purchaser's license fee.
70.74.140 - Storage license fee.
70.74.142 - User's license or renewal—Fee.
70.74.146 - Seller's license fee—Sellers to comply with dealer requirements.
70.74.150 - Annual inspection.
70.74.160 - Unlawful access to explosives.
70.74.170 - Discharge of firearms or igniting flame near explosives.
70.74.180 - Explosive devices prohibited—Penalty.
70.74.201 - Municipal or county ordinances unaffected—State preemption.
70.74.210 - Coal mining code unaffected.
70.74.230 - Shipments out of state—Dealer's records.
70.74.240 - Sale to unlicensed person prohibited.
70.74.250 - Blasting near fur farms and hatcheries.
70.74.270 - Malicious placement of an explosive—Penalties.
70.74.272 - Malicious placement of an imitation device—Penalties.
70.74.275 - Intimidation or harassment with an explosive—Class C felony.
70.74.280 - Malicious explosion of a substance—Penalties.
70.74.285 - "Terrorist act" defined.
70.74.295 - Abandonment of explosives.
70.74.297 - Separate storage of components capable of detonation when mixed.
70.74.300 - Explosive containers to be marked—Penalty.
70.74.310 - Gas bombs, explosives, stink bombs, etc.
70.74.320 - Small arms ammunition, primers and propellants—Transportation regulations.
70.74.330 - Small arms ammunition, primers and propellants—Separation from flammable materials.
70.74.370 - License revocation, nonrenewal, or suspension.
70.74.380 - Licenses—Expiration—Extension of storage licenses.
70.74.390 - Implementation of chapter and rules pursuant to chapter 49.17 RCW.