Effective: June 14, 2000
Latest Legislation: House Bill 601 - 123rd General Assembly
(A) The chief of the division of mineral resources management or the chief's representative shall require installation on a longwall working section of a federally approved methane monitor capable of giving warning automatically when the concentration of methane reaches a maximum percentage of not more than 1.0 volume per cent of methane. The sensoring unit indicating the atmospheric conditions on the methane monitor shall be installed at a location specified in the approved plan or revision required by section 1567.69 of the Revised Code.
The operator shall ensure that the methane monitor is kept operative and properly maintained and tested weekly for functioning.
The operator of any mine in which longwall mining is performed shall establish and adopt a definite maintenance program designed to keep methane monitors operative, and a written description of the program shall be available for inspection by the division of mineral resources management. At least once each month, the operator shall have the methane monitor checked for operating accuracy with a known methane air mixture and shall have the monitor calibrated as necessary. The operator shall keep a record of calibration tests in a book on the surface, which may be the same book used to comply with requirements established under regulations of the mine safety and health administration in the United States department of labor.
If the methane monitor on a longwall working section malfunctions, the operator shall have the monitor repaired within twelve hours. During the period of time the methane monitor is inoperative, the operator shall not permit electric equipment to be operated for longer than ten minutes without an examination for methane gas, shall require that the examinations required in division (B) of this section be conducted on one-hour intervals, and shall require an air reading on the intake side of the longwall working face to be collected on one-hour intervals.
If parts are unavailable to correct the malfunction of the methane monitor or the malfunction cannot be repaired within twelve hours, the operator shall immediately notify the division, which shall evaluate the circumstances and may allow continued operation under the procedures of the preceding paragraph if the operator is proceeding with good faith efforts to correct the malfunction.
If a malfunction of the methane monitor occurs on a longwall working section, the supervisor on duty shall indicate in the supervisor's own shift examination report, in the fire boss report books, the date and time the methane monitor malfunctioned.
(B) A certified person designated by the mine foreperson to supervise a longwall working section shall examine the longwall working face for hazards as a part of the pre-shift and on-shift examinations for each coal producing shift and more often if necessary for safety or required by division (A) of this section. The examination shall include a test for methane gas and oxygen deficiency. The methane and oxygen deficiency examinations shall be made at reasonable intervals along the coal face between the headgate and tailgate. The person's initials, date, and time shall be recorded at the headgate and tailgate. If one per cent or more of methane gas is detected along the coal face, the electrical equipment shall be immediately de-energized and the electrical power circuit then disconnected from the power supply until a certified person pronounces the place safe.
Structure Ohio Revised Code
Title 15 | Conservation of Natural Resources
Chapter 1567 | Mine Equipment; Safety Provisions
Section 1567.01 | Chapter Does Not Apply to Chapter 1514 Activities.
Section 1567.02 | Use of Present Machinery Lawful - Replacement of Appliances and Machinery.
Section 1567.03 | Prohibited Acts.
Section 1567.04 | Machine Runners and Helpers.
Section 1567.05 | Trespassing.
Section 1567.06 | Examination of Mine Generating Firedamp - Posting or Report.
Section 1567.07 | Entry Beyond Danger Signal.
Section 1567.08 | Book of Reports of Mine Condition and Air Measurements.
Section 1567.09 | Ventilation of Mines.
Section 1567.10 | Ventilating Fans.
Section 1567.11 | Booster and Blower Fans.
Section 1567.12 | Accident to Ventilating Fan.
Section 1567.13 | Supervision of Ventilating Apparatus and Airways.
Section 1567.14 | Entry Into Mine After Interruption of Ventilation.
Section 1567.15 | Closing of Ventilating Doors.
Section 1567.16 | Electrical System - Prohibited Activities.
Section 1567.17 | Rules for Use of Direct Current.
Section 1567.18 | Rules for Use of Alternating Current.
Section 1567.19 | Grounding of Machines and Armored Cable Using Alternating Current.
Section 1567.20 | Electrical Equipment to Be Grounded.
Section 1567.21 | Employment of Shot Firers.
Section 1567.22 | Use of Black Powder.
Section 1567.23 | Handling Explosives in Mines.
Section 1567.24 | Conveyance of Explosives.
Section 1567.25 | Explosives to Be Protected From Contact With Fire.
Section 1567.26 | Explosives and Tools on Cages or Stairways.
Section 1567.27 | Use of Squibs and Fuses - Tamping.
Section 1567.30 | Firing of Shots - Appointed Times.
Section 1567.31 | Drill Holes.
Section 1567.32 | Misfired Shots.
Section 1567.33 | Examination After Each Blast.
Section 1567.34 | Solid Shooting.
Section 1567.35 | Use of Gasoline, Naphtha, Kerosene, Fuel Oil or Gas Engine.
Section 1567.36 | Fire Extinguishers.
Section 1567.38 | Use of Locomotive and Haulage Equipment.
Section 1567.40 | Riding on Haulage Trips.
Section 1567.41 | Operation of Trolley Ahead of Locomotive.
Section 1567.42 | Riding on Locomotive or Cars.
Section 1567.43 | Signal Light.
Section 1567.44 | Handling Cars.
Section 1567.46 | Windlass Required.
Section 1567.47 | Qualifications of Persons in Charge of Hoisting Engine.
Section 1567.48 | Safe Appliances for Ingress and Egress in Shaft.
Section 1567.49 | Lowering and Hoisting of Persons by Vertical Shaft.
Section 1567.50 | Regulations for Speaking Tube, Cages, and Safety Gate.
Section 1567.51 | Signal Code.
Section 1567.52 | Additions to Code of Signals - Posting.
Section 1567.53 | Emergency Signal in Vertical Shaft.
Section 1567.54 | Adequate Fire Protection - Firefighting Equipment.
Section 1567.55 | Report of Coal Seam Fire - Covering of Exposed Surface to Prevent Fire.
Section 1567.57 | Two-Way Communication System.
Section 1567.58 | Lights in Mines.
Section 1567.59 | Flame Safety Lamps.
Section 1567.60 | Recording Pressure Gauge.
Section 1567.62 | Obstruction of Airway.
Section 1567.63 | Use of Traveling Ways - Loitering Prohibited.
Section 1567.64 | Operator to Provide Tag Lines or Tie-Off Lines for Miners.
Section 1567.65 | Prohibition Against Smoking or Carrying Smoking Materials.
Section 1567.66 | Prohibition Against Intoxicants.
Section 1567.67 | Protective Clothing.
Section 1567.68 | Safety Provisions for Machinery and Equipment.
Section 1567.681 | Fire Detection Devices Required on Conveyor Belts.
Section 1567.69 | Longwall Mining Plans or Revisions - Contents.
Section 1567.70 | Plan for Recovery of Longwall Roof Support - Approval by Chief.
Section 1567.71 | Two-Way Communication Facilities.
Section 1567.72 | De-Energizing Electrical Power on Longwall Working Face Conveyor.
Section 1567.73 | Installation of Methane Monitors.
Section 1567.74 | Safety Requirements for Longwall Working Face.
Section 1567.75 | Cutting and Welding.
Section 1567.76 | Maintenance of Hydraulic Lines and Roof Support Units.
Section 1567.77 | First Aid Equipment.
Section 1567.78 | Maintaining Accessible Tailgate Travel Route.