Ohio Revised Code
Chapter 1567 | Mine Equipment; Safety Provisions
Section 1567.72 | De-Energizing Electrical Power on Longwall Working Face Conveyor.

Effective: October 29, 1995
Latest Legislation: Senate Bill 162 - 121st General Assembly
(A) An operator conducting longwall mining shall provide all longwall working face conveyors installed on and after the effective date of this section with lock-out type de-energizing devices to de-energize the electrical power on the longwall working face conveyor. The de-energizing devices shall be provided at intervals of not more than fifty feet when the average height of the coal seam is at or below forty-eight inches and at intervals of not more than one hundred feet when the average height of the coal seam is above forty-eight inches. The lock-out de-energizing may be done electrically.
(B) Within twelve months after the effective date of this section, an operator shall provide all longwall working sections in operation prior to the effective date of this section with lock-out type de-energizing devices on face conveyors as required in division (A) of this section.
(C) The operator shall provide on the headgate of the longwall working section an emergency de-energizing device to de-energize immediately the longwall working face equipment.
(D) At the beginning of each coal producing shift, all emergency de-energizing devices shall be checked for proper functioning and, if an emergency de-energizing device is found malfunctioning, mining operations shall not begin until all de-energizing devices within the intervals required by division (A) of this section are functioning properly or until a designated person is stationed at the next de-energizing device at the interval required under division (A) of this section until such time as the malfunctioning de-energizing device is repaired.
(E) If, during a coal producing shift, a de-energizing device malfunctions, which creates an interval greater than that required by division (A) of this section, a designated person shall be stationed at the next de-energizing device at the interval required under division (A) of this section until such time as the malfunctioning de-energizing device is repaired or the machine is de-energized and locked out.
(F) No operator shall permit longwall mining to begin or continue at any time that more than one of the de-energizing devices required under division (A) of this section is malfunctioning. If the malfunctions create intervals greater than those required under that division, except as provided in division (E) of this section.
(G) No operator shall install or use a longwall working face conveyor unless its electrical circuits are designed so that the face conveyor will not start at any other location until the lock-out device is disengaged at the point of initial interruption.
(H) No operator shall provide or permit use of shearer and plow motors on a longwall working section that are not designed so that their cutting bits cannot begin operating when electrical power is initially applied.
(I) No person shall perform work on the face conveyor or on the face side of the face conveyor unless equipment is de-energized and locked out, except when motion facilitates troubleshooting or positioning for maintenance or repair.

Structure Ohio Revised Code

Ohio Revised Code

Title 15 | Conservation of Natural Resources

Chapter 1567 | Mine Equipment; Safety Provisions

Section 1567.01 | Chapter Does Not Apply to Chapter 1514 Activities.

Section 1567.02 | Use of Present Machinery Lawful - Replacement of Appliances and Machinery.

Section 1567.03 | Prohibited Acts.

Section 1567.04 | Machine Runners and Helpers.

Section 1567.05 | Trespassing.

Section 1567.06 | Examination of Mine Generating Firedamp - Posting or Report.

Section 1567.07 | Entry Beyond Danger Signal.

Section 1567.08 | Book of Reports of Mine Condition and Air Measurements.

Section 1567.09 | Ventilation of Mines.

Section 1567.10 | Ventilating Fans.

Section 1567.11 | Booster and Blower Fans.

Section 1567.12 | Accident to Ventilating Fan.

Section 1567.13 | Supervision of Ventilating Apparatus and Airways.

Section 1567.14 | Entry Into Mine After Interruption of Ventilation.

Section 1567.15 | Closing of Ventilating Doors.

Section 1567.16 | Electrical System - Prohibited Activities.

Section 1567.17 | Rules for Use of Direct Current.

Section 1567.18 | Rules for Use of Alternating Current.

Section 1567.19 | Grounding of Machines and Armored Cable Using Alternating Current.

Section 1567.20 | Electrical Equipment to Be Grounded.

Section 1567.21 | Employment of Shot Firers.

Section 1567.22 | Use of Black Powder.

Section 1567.23 | Handling Explosives in Mines.

Section 1567.24 | Conveyance of Explosives.

Section 1567.25 | Explosives to Be Protected From Contact With Fire.

Section 1567.26 | Explosives and Tools on Cages or Stairways.

Section 1567.27 | Use of Squibs and Fuses - Tamping.

Section 1567.30 | Firing of Shots - Appointed Times.

Section 1567.31 | Drill Holes.

Section 1567.32 | Misfired Shots.

Section 1567.33 | Examination After Each Blast.

Section 1567.34 | Solid Shooting.

Section 1567.35 | Use of Gasoline, Naphtha, Kerosene, Fuel Oil or Gas Engine.

Section 1567.36 | Fire Extinguishers.

Section 1567.38 | Use of Locomotive and Haulage Equipment.

Section 1567.39 | Lights and Signals for Locomotives and Cars - Riding on Locomotive - Protection Against Runaway or Self-Propelled Equipment.

Section 1567.40 | Riding on Haulage Trips.

Section 1567.41 | Operation of Trolley Ahead of Locomotive.

Section 1567.42 | Riding on Locomotive or Cars.

Section 1567.43 | Signal Light.

Section 1567.44 | Handling Cars.

Section 1567.45 | Limitation on Number of Persons in Cage or Elevator - Hoisting Equipment Safety Examination.

Section 1567.46 | Windlass Required.

Section 1567.47 | Qualifications of Persons in Charge of Hoisting Engine.

Section 1567.48 | Safe Appliances for Ingress and Egress in Shaft.

Section 1567.49 | Lowering and Hoisting of Persons by Vertical Shaft.

Section 1567.50 | Regulations for Speaking Tube, Cages, and Safety Gate.

Section 1567.51 | Signal Code.

Section 1567.52 | Additions to Code of Signals - Posting.

Section 1567.53 | Emergency Signal in Vertical Shaft.

Section 1567.54 | Adequate Fire Protection - Firefighting Equipment.

Section 1567.55 | Report of Coal Seam Fire - Covering of Exposed Surface to Prevent Fire.

Section 1567.57 | Two-Way Communication System.

Section 1567.58 | Lights in Mines.

Section 1567.59 | Flame Safety Lamps.

Section 1567.60 | Recording Pressure Gauge.

Section 1567.61 | First Aid and Emergency Medical Equipment - Report of Arrangements for Emergency Medical Assistance and Transportation.

Section 1567.62 | Obstruction of Airway.

Section 1567.63 | Use of Traveling Ways - Loitering Prohibited.

Section 1567.64 | Operator to Provide Tag Lines or Tie-Off Lines for Miners.

Section 1567.65 | Prohibition Against Smoking or Carrying Smoking Materials.

Section 1567.66 | Prohibition Against Intoxicants.

Section 1567.67 | Protective Clothing.

Section 1567.68 | Safety Provisions for Machinery and Equipment.

Section 1567.681 | Fire Detection Devices Required on Conveyor Belts.

Section 1567.69 | Longwall Mining Plans or Revisions - Contents.

Section 1567.70 | Plan for Recovery of Longwall Roof Support - Approval by Chief.

Section 1567.71 | Two-Way Communication Facilities.

Section 1567.72 | De-Energizing Electrical Power on Longwall Working Face Conveyor.

Section 1567.73 | Installation of Methane Monitors.

Section 1567.74 | Safety Requirements for Longwall Working Face.

Section 1567.75 | Cutting and Welding.

Section 1567.76 | Maintenance of Hydraulic Lines and Roof Support Units.

Section 1567.77 | First Aid Equipment.

Section 1567.78 | Maintaining Accessible Tailgate Travel Route.

Section 1567.79 | Instruction on Hazards.

Section 1567.99 | Penalty.