New York Laws
Title 3 - Fire Hazard
264 - Fireproof Building.

(1) If the windows are located more than thirty feet horizontally or
fifty feet vertically from the nearest opening in the wall of another
building.
(2) If the windows are located more than fifty feet in a vertical
direction above the roof of a building within a horizontal distance of
thirty feet of the wall in which the said windows are located.
7. Partitions. All partitions in the interior of fireproof buildings
shall be of incombustible material. Nothing in this section shall
prevent the use, in a building equipped with automatic sprinklers, of
subdividing partitions of wood, or of wood and glass, in spaces used
solely for office or show-room purposes, provided, however, that where
such spaces are contiguous to any room or rooms in which manufacturing
is carried on, such spaces shall be separated from such room or rooms by
a dividing partition which, including doors, is constructed of
incombustible material.