(a) Subject to subsection (c) of this section, any new or replacement piping that is buried or installed for the purposes of connecting a building to a water supply system, a sewerage system, an underground storm drain system, or any other applicable device shall be buried or installed with a wire or an equivalent product or technology that makes the piping detectable or locatable.
(b) Any wire used to comply with subsection (a) of this section shall:
(1) be an insulated copper tracer wire that is suitable for direct burial and has an American wire gauge (AWG) of at least 10, or an equivalent product;
(2) be installed:
(i) in the same trench as the piping that connects the building to the water supply system or the sewerage system;
(ii) within 12 inches of the piping that connects the building to the water supply system or the sewerage system; and
(iii) with at least one end of the wire terminating above grade in a location that is accessible and resistant to physical damage, such as in a cleanout or next to an external wall of the building; and
(3) run from within 5 feet of an external wall of the building to:
(i) the point where the piping intersects with the water supply system or the sewerage system; or
(ii) the point where the sewerage system disposes of or processes the sewage.
(c) The requirement of subsection (a) of this section with regard to replacement piping connecting a building to a water supply system or a sewerage system:
(1) applies only to a complete replacement of the piping; and
(2) does not apply to a repair or a partial replacement of the piping.
Structure Maryland Statutes
Division I - Public Services and Utilities
Title 12 - Underground Facilities
Subtitle 1 - Excavation or Demolition Near Underground Facilities
Part IV - Excavation and Demolition
Section 12-120 - Effect of Subtitle
Section 12-121 - Emergency Excavation or Demolition
Section 12-123 - Owner-Member of One-Call System
Section 12-124 - Notice to One-Call System
Section 12-125 - Repeat Notification
Section 12-126 - Marking Requirements
Section 12-127 - Excavation After Notice That Facilities Marked or Not in Vicinity
Section 12-129 - Detectable Wires for Connecting Buildings to Water Supply or Sewerage Systems