RCW 49.24.080
Requirements for underground labor.
Every person, firm or corporation constructing, building or operating a tunnel, quarry, caisson or subway, excepting in connection with mines, with or without compressed air, shall in the employment of any labor comply with the following safety provisions:
(1) A safety miner shall be selected by the crew on each shift who shall check the conditions necessary to make the working place safe; such as loose rock, faulty timbers, poor rails, lights, ladders, scaffolds, fan pipes and firing lines.
(2) Ventilating fans shall be installed from twenty-five to one hundred feet outside the portal.
(3) No employee shall be allowed to "bar down" without the assistance of another employee.
(4) No employee shall be permitted to return to the heading until at least thirty minutes after blasting.
(5) Whenever persons are employed in wet places, the employer shall furnish such persons with rubbers, boots, coats and hats. All boots if worn previously by an employee shall be sterilized before being furnished to another: PROVIDED, That RCW 49.24.080 through 49.24.380 shall not apply to the operation of a railroad except that new construction of tunnels, caissons or subways in connection therewith shall be subject to the provisions of RCW 49.24.080 through 49.24.380: PROVIDED, FURTHER, That in the event of repair work being done in a railroad tunnel, no person shall be compelled to perform labor until the air has been cleared of smoke, gas and fumes.
[ 1973 1st ex.s. c 154 § 89; 1965 c 144 § 1; 1941 c 194 § 1; Rem. Supp. 1941 § 7666-9.]
NOTES:
Severability—1973 1st ex.s. c 154: See note following RCW 2.12.030.
Structure Revised Code of Washington
Chapter 49.24 - Health and Safety—Underground Workers.
49.24.020 - Compressed air safety requirements.
49.24.030 - Medical and nursing attendants.
49.24.040 - Examination as to physical fitness.
49.24.080 - Requirements for underground labor.
49.24.100 - Lighting appliances.
49.24.130 - Air chambers—Hanging walks.
49.24.150 - Explosives and detonators.
49.24.160 - Air plant—Feed water.
49.24.170 - Electric power requirements.
49.24.190 - Cars, cages, buckets—Employees riding or walking.
49.24.200 - Speed of vehicles.
49.24.210 - Oil supply restricted.
49.24.220 - Explosives, use of—Blasting.
49.24.230 - Firing switch—Warning by blaster.
49.24.240 - Inspection after blast.
49.24.260 - Requirements as to caissons.
49.24.270 - Shields to be provided.
49.24.280 - Caissons to be braced.
49.24.290 - Cages—Hoisting apparatus.
49.24.300 - Buckets in vertical shafts.
49.24.310 - Telephone system for tunnels.
49.24.320 - Location of lights.
49.24.330 - Generators, transformers, etc., to be grounded.
49.24.340 - Electrical voltage.
49.24.350 - Lamps to be held in reserve.
49.24.360 - Insulators required.