§2105. Inspection procedure
The Bureau of Labor Standards shall adopt an inspection procedure for self-contained breathing apparatus. The procedure must include at least the following, as specified in the manufacturer's operation manual: [PL 2017, c. 219, §19 (AMD).]
1. All components, air supply devices, personal alert safety system devices and warning devices. A complete inspection of all components, air supply devices, personal alert safety system devices and warning devices to be performed after each use and:
A. For volunteer associations and on-call fire departments, every month; and [PL 1987, c. 356 (NEW).]
B. For full-time fire departments, every week; [PL 1987, c. 356 (NEW).]
[PL 2003, c. 570, §6 (AMD); PL 2003, c. 570, §7 (AFF).]
2. Facepiece. Cleansing and sanitizing the facepiece after each use; and
[PL 1987, c. 356 (NEW).]
3. Record. A record of the date of each inspection and findings for each self-contained breathing apparatus.
[PL 1987, c. 356 (NEW).]
SECTION HISTORY
PL 1987, c. 356 (NEW). PL 2003, c. 570, §6 (AMD). PL 2003, c. 570, §7 (AFF). PL 2017, c. 219, §19 (AMD).